Fluorospheres and Quality Control
Beckman Coulter provides a complete comprehensive workflow solution for all your flow cytometry needs.
Description
Utility
Fluorospheres
Emission Range Excitation 525 nm – 700 nm 488 nm 515 nm – 800 nm 488 nm 640 nm – 800 nm 635 nm 400 nm – 500 nm 405 nm
Flow-Check Fluorospheres
Used for daily verification of a flow cytometer’s optical alignment and fluidics system
Flow-Check Pro Fluorospheres
Used for daily verification of optical alignment and fluidics of flow cytometers
configured with multiple laser (Blue, Red, and Violet)
Flow-Set Fluorospheres
Used for standardization of flow cytometers for analysis of human leukocytes
525 nm – 700 nm 488 nm
Flow-Set Pro Fluorospheres
Used for standardization of flow cytometers configured with Multiple laser (Blue, Red,
515 nm – 800 nm 488 nm 640 nm – 800 nm 635 nm 400 nm – 500 nm 405 nm
and Violet), for quantitative analysis of human leukocytes
IMMUNO-BRITE Fluorospheres
Used to monitor instrument linearity. Fluorospheres uniform in size, with varying
525 nm – 700 nm 488 nm
fluorescent intensities.
Flow-Count Fluorospheres
Used to determine absolute counts on the flow cytometer
525 nm – 700 nm 488 nm
Quality Controls CYTO-COMP Cell Kit
Lyophilized human lymphocytes used in conjunction with Cyto-Comp Reagent kit or the Quick Comp Reagent kits to establish and monitor compensation settings for multicolor analysis Preparation of 4 vials of 2-Color reagents. Used to establish and monitor color compensation settings in conjunction with the Cyto-COMP cell kit, for multicolor analysis
CYTO-COMP Reagent Kit,
CYTO-TROL Control Cells
Lyophilized human lymphocytes used to assess activity of monoclonal antibodies
IMMUNO-TROL Cells
Whole blood based lysable positive process control for immunophenotyping analysis using monoclonal antibody reagents and flow cytometry Whole blood based lysable positive process control for immunophenotyping analysis using monoclonal antibody reagents and flow cytometry, targeted for low level CD4 counts
IMMUNO-TROL Low Cells
AQUIOS IMMUNO-TROL Cells Verification of instrument and reagent performance. AQUIOS IMMUNO-TROL Low Cells Allows verification of instrument and reagent performance. QuickCOMP 2 Kit
2 single-color reagents comprised of one monoclonal antibody each labeled with FITC or PE conjugated antibodies for adjusting color compensation with flow cytometers performing full matrix compensation 4 single-color fluorescent reagents comprised of one monoclonal antibody each labeled with FITC, PE, ECD, or PC5 conjugated antibodies for adjusting color compensation equipped with flow cytometers performing full matrix compensation 2 color fluorescent reagents implementing two monoclonal antibodies conjugated to FITC and PE, set to adjust color compensation for automated or manual analysis with the Stem kit reagent
QuickCOMP 4 Kit
Stem-Comp Reagent
Ready-to-use highly calibrated control cells providing antibody-to-antigen positive control for absolute counting of CD34 + CD45 dim cells
Stem-Trol Control Cells
SUPPORT REAGENTS