Flow Cytometry catalog - US 2019

Fluorospheres and Quality Control

Beckman Coulter provides a complete comprehensive workflow solution for all your flow cytometry needs.

Description

Utility

Fluorospheres

Emission Range Excitation 525 nm – 700 nm 488 nm 515 nm – 800 nm 488 nm 640 nm – 800 nm 635 nm 400 nm – 500 nm 405 nm

Flow-Check Fluorospheres

Used for daily verification of a flow cytometer’s optical alignment and fluidics system

Flow-Check Pro Fluorospheres

Used for daily verification of optical alignment and fluidics of flow cytometers

configured with multiple laser (Blue, Red, and Violet)

Flow-Set Fluorospheres

Used for standardization of flow cytometers for analysis of human leukocytes

525 nm – 700 nm 488 nm

Flow-Set Pro Fluorospheres

Used for standardization of flow cytometers configured with Multiple laser (Blue, Red,

515 nm – 800 nm 488 nm 640 nm – 800 nm 635 nm 400 nm – 500 nm 405 nm

and Violet), for quantitative analysis of human leukocytes

IMMUNO-BRITE Fluorospheres

Used to monitor instrument linearity. Fluorospheres uniform in size, with varying

525 nm – 700 nm 488 nm

fluorescent intensities.

Flow-Count Fluorospheres

Used to determine absolute counts on the flow cytometer

525 nm – 700 nm 488 nm

Quality Controls CYTO-COMP Cell Kit

Lyophilized human lymphocytes used in conjunction with Cyto-Comp Reagent kit or the Quick Comp Reagent kits to establish and monitor compensation settings for multicolor analysis Preparation of 4 vials of 2-Color reagents. Used to establish and monitor color compensation settings in conjunction with the Cyto-COMP cell kit, for multicolor analysis

CYTO-COMP Reagent Kit,

CYTO-TROL Control Cells

Lyophilized human lymphocytes used to assess activity of monoclonal antibodies

IMMUNO-TROL Cells

Whole blood based lysable positive process control for immunophenotyping analysis using monoclonal antibody reagents and flow cytometry Whole blood based lysable positive process control for immunophenotyping analysis using monoclonal antibody reagents and flow cytometry, targeted for low level CD4 counts

IMMUNO-TROL Low Cells

AQUIOS IMMUNO-TROL Cells Verification of instrument and reagent performance. AQUIOS IMMUNO-TROL Low Cells Allows verification of instrument and reagent performance. QuickCOMP 2 Kit

2 single-color reagents comprised of one monoclonal antibody each labeled with FITC or PE conjugated antibodies for adjusting color compensation with flow cytometers performing full matrix compensation 4 single-color fluorescent reagents comprised of one monoclonal antibody each labeled with FITC, PE, ECD, or PC5 conjugated antibodies for adjusting color compensation equipped with flow cytometers performing full matrix compensation 2 color fluorescent reagents implementing two monoclonal antibodies conjugated to FITC and PE, set to adjust color compensation for automated or manual analysis with the Stem kit reagent

QuickCOMP 4 Kit

Stem-Comp Reagent

Ready-to-use highly calibrated control cells providing antibody-to-antigen positive control for absolute counting of CD34 + CD45 dim cells

Stem-Trol Control Cells

SUPPORT REAGENTS

152

US Clinical Diagnostics Catalog

Made with FlippingBook flipbook maker