AQUIOS Reagents

AQUIOS reagents are optimized for peak performance when used with the AQUIOS CL Flow Cytometer. High reliability with no need to mix your monoclonal antibodies.

The AQUIOS reagents use a unique barcode identity for tracking reagent type, lot number, container number, expiration dates, and remaining reagent levels. The reagent consumption is monitored by the system as the samples are processed.

Samples are stained, incubated and lysed onboard in 96-well microplates.

AQUIOS TETRA In the clinical management of immune deficiency diseases, accurately counting the absolute cell numbers of leukocyte subsets and measuring the percentage of individual subtypes in blood is critical. The AQUIOS CL flow cytometer in combination with AQUIOS Tetra reagents provides a Single Platform Technology (SPT) for lymphocyte subset analysis and enumeration without the need for counting beads. AQUIOS Tetra-1 Panel and AQUIOS Tetra-2+ Panel monoclonal antibody reagents are for use on the AQUIOS CL Flow Cytometer with peripheral whole blood for immunophenotyping. These reagents are indicated for use in the immunologic assessment of patients having, or suspected of having, immune deficiency.

AQUIOS Tetra-1 Panel

Size

Status

Part #

B23533 50 tests IVD & CE AQUIOS Tetra-1 Panel Monoclonal Antibody Reagents is a four-color monoclonal antibody cocktail consisting of CD45-FITC/CD4-RD1/CD8- ECD/CD3-PC5, and is used in the identification and enumeration of total CD3+, CD3+CD4+, CD3+CD8+, CD3+CD4+/CD3+CD8+ (ratio only) lymphocyte percentages and absolute counts in peripheral whole blood, plus the CD45+ absolute count and CD45+ Low SS (lymphocytes) percentage and absolute count. The formulation is optimized for high performance on the AQUIOS Flow Cytometer system: no experimenting, mixing or other pre-analysis work is necessary. The AQUIOS Tetra-1 Panel is ready to use. AQUIOS monoclonal reagent vials are cap pierce-able so there is no need to uncap and recap the vials every day. The vials are barcoded , which allows the user to load the vials in any random position. LOAD the vial in the carousel onboard the system, and GO. The system does the rest. High volume laboratories may load multiple vials in the reagent carousel and the system will automatically detect their presence and move from one vial to the next as needed.

Clone

Isotype

Combination

B3821F4A SFCI12T4D11 SFCI21Thy2D3

IgG2b (mouse) IgG1 (mouse) IgG1 (mouse) IgG1 (mouse)

CD45-FITC CD4-RD1 CD8-ECD CD3-PC5

UCHT1

AQUIOS Tetra-2+ Panel

Size

Status

Part #

B23534 50 tests IVD & CE AQUIOS Tetra-2+ Panel Monoclonal Antibody Reagents is a four-color monoclonal antibody cocktail consisting of CD45-FITC/(CD56 + CD16)- RD1/CD19-ECD/CD3-PC5, and is used in the identification and enumeration of total CD3+, CD3-CD19+, CD3-CD56+ and/or CD16+ lymphocyte percentages and absolute counts in peripheral whole blood, plus the CD45+ absolute count and CD45+ Low SS (lymphocytes) percentage and absolute count. The formulation is optimized for high performance on the AQUIOS Flow Cytometer system: no experimenting, mixing or other pre-analysis work is necessary. The AQUIOS Tetra-2+ Panel is ready to use. AQUIOS monoclonal reagent vials are cap pierce-able so there is no need to uncap and recap the vials every day. The vials are barcoded , which allows the user to load the vials in any random position. LOAD the vial in the carousel onboard the system, and GO. The system does the rest. High volume laboratories may load multiple vials in the reagent carousel and the system will automatically detect their presence and move from one vial to the next as needed.

Clone

Isotype

Combination

B3821F4A 3G8+N901

IgG2b (mouse) IgG1 (mouse) IgG1 (mouse) IgG1 (mouse)

CD45-FITC

(CD16+CD56)-RD1

J3-119 UCHT1

CD19-ECD CD3-PC5